Classify the source without mixing levels
Each row starts with its source: regulation, standard, guidance or contract. Standards are generally voluntary, but regulatory or contractual references can make them binding within a defined context. Guidance supports interpretation; it does not replace the source creating an obligation. Identify title, issuer, edition, country, effective date and actual clause used. A catalogue event date is not automatically an edition date. Do not apply a new publication to an old contract without checking the agreed reference. Document or interface language determines neither jurisdiction nor scope. Record the basis of each obligation separately so another reviewer can inspect it.
Connect conditions to project facts
For each requirement, state the applicability condition and facts that test it: use, operation, defined area, relevant system, qualified capacity or project date. Retain each fact’s source. Use three distinct statuses: applicable with reasons, not applicable with reasons, and to confirm because evidence is missing. A filled field does not prove that its value matches the required definition. In the BACS scenario, pump electrical power alone cannot establish useful system capacity. Record what is missing, who can supply it and which decision remains open. Never turn absent information into an automatic exemption.
Bound the decision and plan its review
The decision must identify IFC revision, checking profile, population, executed criteria, exclusions and exceptions. Distinguish data correction, exchange validity and physical asset performance. A FireRating presence check does not verify fire resistance; a fictional exercise instruction does not become real evidence. Assign producer, checker and acceptance authority without inventing a human approval. Define review triggers: changed use, equipment replacement, new revision, changed applicable text or a new exception. The record should allow reasoning to be reproduced and reveal when the conclusion is no longer sufficient. A percentage without that context cannot communicate acceptance responsibly.
Worked example
For the Duplex door, a row can conclude that the exercise property was corrected against EX-D01-revB, preserving identity and passing re-read. Actual fire performance remains unestablished: the document is fictional and the check educational.
Source + status + editionCondition + verified factsEvidence / missing informationReasoned decision + owner + review
Questions and answers
System use and useful capacity are missing. Which BACS applicability status is justified?
To confirm, listing missing information and reviewing responsibility Missing information proves neither exemption nor obligation. Document context and arrange a competent decision.
System use and useful capacity are missing. Which BACS applicability status is justified?
To confirm, listing missing information and reviewing responsibility Missing information proves neither exemption nor obligation. Document context and arrange a competent decision.
Put it into practice
Review cards and solve cases
Start free training →Worked example IFC →Official sources
- Normes, règlements et contrats
- NF EN ISO 7817-1
- NF EN ISO 19650-4
- BACS · guide ministériel janvier 2026
- Directive (UE) 2024/1275 · EPBD
Content references: 30 October 2026. Consult the sources to verify their version and applicability.
Published by BIMCheck Consulting · Publisher: Winter Fernandes
Content references: 30 October 2026. Consult the sources to verify their version and applicability.
Independent, non-certifying training. Check the IFC schema, standards edition and project-specific requirements.
About and editorial method