Schema describes possibilities; the file records facts

An IFC schema defines available classes, attributes, value types and relationships. A file contains instances of those definitions. Reading FILE_SCHEMA is therefore an initial checking step before choosing filters. A pump can be represented differently according to version and export strategy. Seeing an object does not prove that required information exists. Conversely, failure to find a recent class in an older schema does not prove the equipment is absent.

Three identifiers, three uses

A STEP number such as #6652 follows a reference within this file and may change on export. GlobalId is the IFC identifier normally preferred when matching deliveries, while its quality must still be checked. Tag and Name can serve users under project conventions; neither is universally unique. Record the key expected by the CMMS, case and whitespace rules, uniqueness scope and its mapping to IFC identity.

Compare a revision without inventing an event

An unchanged GlobalId with a changed STEP number may represent the same object exported differently. A changed serial requires investigation: entry correction, physical replacement, type change or import error. Retain both values, source versions, date, author and decision. Never infer physical replacement from STEP numbering alone. A replaced asset may require a new business identity and an explicit link to the retired asset.

Prove the comparison

A reproducible comparison identifies files, hashes, schema, selected population and matching rules. Test a duplicate key and a removed object, not just successful matching. Separate addition, removal, modification and unassessed information. Useful evidence lets another person locate the same object and change. It does not turn a computer report into an automatic statement of a building’s physical condition.

Worked example

In Duplex, door #6652 has GlobalId 1hOSvn6df7F8_7GcBWlRGQ. Correcting FireRating should retain identity and trace the changed property, without claiming real fire performance.

  1. FILE_SCHEMA
  2. IFC class
  3. GlobalId ↔ CMMS key
  4. Revision + evidence

Questions and answers

A pump is visible in 3D, but location and manual are missing. What is supported?

The representation is visible; operational readiness still needs checking. A graphic representation proves neither business completeness nor a schema defect. Check information needed for the operational decision.

Two revisions retain GlobalId but change STEP ID and serial. What first analysis?

Match identity, then inspect serial change and history A stable key supports comparison without explaining the event. Check correction, replacement, author, date and business evidence.

Put it into practice

Review cards and solve cases

Start free training →Worked example IFC →

Official sources

Content references: 30 October 2026. Consult the sources to verify their version and applicability.

Published by BIMCheck Consulting · Publisher: Winter Fernandes

Content references: 30 October 2026. Consult the sources to verify their version and applicability.

Independent, non-certifying training. Check the IFC schema, standards edition and project-specific requirements.

About and editorial method