The path matters as much as the label

A single-value property includes Name, NominalValue and an optional Unit. Its set also has a name and identifier. Specify Pset.Property, value type and checked object. A Flow label may mean mass or volumetric flow under different conditions. Translating the label does not prove equivalence. A usable definition states quantity, unit, allowed values, source and version; a template describes structure rather than an actual equipment measurement.

Inheritance and partial overrides

Resolve values by checking occurrence Psets and the type linked through IfcRelDefinesByType. Type Psets may be referenced through HasPropertySets. For the same set and property, occurrence values prevail while other inherited values remain. With type A=1, B=2 and occurrence A=9, resolve A=9, B=2. Retain provenance and the linking relationship. The word Type within a Pset name is not evidence of typing.

Missing, zero and FALSE

In these STEP exercises, $ means an unspecified value and * a derived value. IFCBOOLEAN(.F.) supplies a value: FALSE is not missing. Zero may be correct or impossible depending on quantity and business rule. The Duplex text Fire Rating is present but describes no verified performance. Presence and value checks answer different questions. Never fill a gap with a plausible guess merely to obtain a green report.

Convert using dimension and evidence

First find an explicit property or quantity unit. If absent, find the project unit for that dimension. For 1,250 mm, conversion to m uses 10⁻³: 1.25 m. For 1,250 mm², use 10⁻⁶: 0.00125 m². Retain source value, unit, factor, target value and rounding rule. Converting kg/s into m³/s also requires an appropriate density; a Flow label alone is insufficient.

Worked example

In Duplex, Thickness #6668 is in PSet_Revit_Type_Dimensions #6724, but relationship #38574 attaches it to door #6652. Its observed origin is occurrence. Export that chain in a mapping without inferring a type from its label.

  1. Occurrence / type
  2. Pset + property
  3. Value + source unit
  4. Resolved value + evidence

Questions and answers

A type has A=1 and B=2. Its occurrence overrides only A=9. Which values resolve?

A=9 ; B=2 For the same Pset and property, the occurrence value prevails. Other type properties remain after a partial override.

Two pumps of one type have different serials. Where should serials be attached?

To each occurrence, with verified provenance A serial identifies an instance. Shared characteristics may be reused, but individual data must remain linked to the correct asset.

Put it into practice

Review cards and solve cases

Start free training →Worked example IFC →

Official sources

Content references: 30 October 2026. Consult the sources to verify their version and applicability.

Published by BIMCheck Consulting · Publisher: Winter Fernandes

Content references: 30 October 2026. Consult the sources to verify their version and applicability.

Independent, non-certifying training. Check the IFC schema, standards edition and project-specific requirements.

About and editorial method